As a discharge device of high and medium frequency lightning current on the floating plate of the external floating top tank, the gap difference between the splitter and the tank wall caused by the micro-deformation of the tank body and the displacement of the floating plate is solved by the adjustable tension device, so as to ensure the timely release of high and medium frequency lightning current on the floating plate and avoid the spark caused by the lightning current release process.

Product Features
● Beryllium bronze /316 material;
● Strong tension;
● Good lightning flow;
● Instead of the coated, upwarped electrostatic guide sheet, can eliminate the hidden danger of spark discharge.
Technical Parameter
● Tilt Angle: 3°~15°
● Shunt plate tension: ≥50N
● Maximum flow rate: > 25KA
● Starting lighting current: > 5KA
● Indirect shock resistance with floating disc: <0.03Ω